Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Fact Sheet: Acid and Base Baths for Glassware Cleaning .

Standard lab attire, lab coat, full-length pants or equivalent, and fully enclosed shoes. Chemical-resistant apron may be worn over the lab coat to protect against splashes. Eye & Face Protection. If there is a splash potential, tight-fitting splash goggles are recommended along with a face shield or protection from a hood sash. Hand Protection

Cleaning Glassware | Protocol

With warm tap water, use an appropriate brush and soapy water to scrub the inside of curved glassware. Remove soapsuds using warm tap water. To avoid hard water stains, use deionized water or reverse osmosis water to wash away tap water. Rinse again with acetone to remove water. This step helps to expedite the glass drying process. 2. General .

General Purpose Water Baths General Purpose Water Baths

PolyScience Water Baths, available in a range of capacities from 2 liters to 28 liters in both economy and digital models, provide the perfect blend of scientific accuracy and utility for day-to-day laboratory tasks. 86-87 Digital 88-89 Economy 90-91 General Purpose Water Bath Accessories General Purpose Water Baths

T06-001A Care and maintenance of water baths

WATER BATHS Technical note: T06-001A Care and maintenance of water baths Introduction The inner containers of the Techne unheated baths are manufactured from grade 304 stainless steel, a material which is extremely hardwearing, easy to clean and with excellent corrosion resistance. The B-8, B-12, B-18 and B-24 inners are deep drawn

Water Baths: Heated, Digital & Shaker Baths - Cole-Parmer

Water baths are ideal for maintaining temperature set points over a long period of time. Different sizes and depths of the bath chamber are available to meet your application. Utility baths are available in analog or digital temperature control with ranges from ambient to 100 degrees C. Options with high-temperature and low-level cutoff .

General Purpose Water Bath at Thomas Scientific

.the water bath during operation to provide a means for condensation to flow back to the chamber; reducing moisture loss and eliminating the accumulation of moisture on laboratory counter tops. Power cords are included on all units. Water baths are UL and CUL listed and refrigerated water baths are.

SOP for Cleaning of Water Bath : Pharmaceutical Guidelines

5.5 Fill purified water up to 3/4 th height of the bath. 5.6 Put the lid of the bath. 5.7 After completion of cleaning of the water bath, record in the format. Note: In between when water becomes dirty follow the same from 5.1 to 5.7 6.0 ABBREVIATIONS 6.1 SOP - Standard Operating Procedure

Standard Operating Procedure Effective Date: Rev.: LCRA .

temperature control use a water bath, a heat-sink incubator, or a properly designed and constructed incubator shown to give equivalent results. A temperature tolerance of 44.5 ± 0.2°C can be obtained with most types of water baths that also are equipped with a gable top for the reduction of water .

Standard Operating Procedure - Purdue University

Standard Operating Procedure Base Bath Ryan Mulvenna, February 2014 Description of Process The base bath is located in FRNY 2182. This piece of equipment is used for etching monolayers of glass in the cleaning of reaction vessels for repeated use. In case of spill/contact with base bath contents wash site with copious amounts of water using

SOP: Cleaning a Laboratory Balance - METTLER TOLEDO

Scope. This SOP describes the procedure for cleaning a laboratory (bench top) balance (both analytical balance and precision balance). It is designed to instruct laboratory personnel on how to proceed for thorough cleaning of a balance.

SOP for Water Bath : Pharmaceutical Guidelines

5.3.4 After completing the calibration make entry in the calibration record of water bath. 6.0 ABBREVIATIONS 6.1 SOP - Standard Operating Procedure 6.2 ºC - Degree centigrade 6.3 DTC - Digital temperature controller

Calibration of temperature control and monitoring devices

Standard Operating Procedure (SOP): A set of instructions having the force of a . nationally or internationally accredited calibration laboratory, using the "ice-water" procedure and it outlines the limitations of this approach. . prove the functionality and stability of the ice-water bath. c. During extended testing periods enough ice .

Keeping Your Laboratory Water Bath Contaminant Free | Lab .

Anyone who has ever incubated anything has also fought contamination at some time—probably many times—and sometimes it starts in a bath. When asked about sample contamination in water baths, David Hayes, product manager for Cole-Parmer Laboratory Equipment & Supplies (Vernon Hills, IL), says, "The effect is as varied as the types of samples that get thawed or brought to a specific .

Standard Operating Procedure (SOP) for ( Cadmium .

Standard Operating Procedure (SOP) for (Cadmium Deposition) . 4. In water bath: Submerge TiO2 substrate in solution at 55 deg. C 5. Transfer solution to waste container . (Insert UC approved Chemical Specific SOPs/Lab Chemical Safety Summaries here) Chemical Hazards and .

Standard Operating Procedure for Base Bath Cleaning .

To make a new base bath, potassium hydroxide (500g) should be first dissolved in 1L water in a beaker. Beware that the solution will become very hot upon dissolution. This solution should be added to 12L of isopropanol in a large Nalgene container. 4. Base Bath Waste Disposal Base bath should be disposed of like any other caustic solution.

Standard Operating Procedures (SOPs) and Good laboratory .

Standard Operating Procedures (SOPs) and Good laboratory Practices (GLPs) for Cell Culture Facilities ARTICLE · NOVEMBER 2014 DOWNLOADS 48 VIEWS 90 1 AUTHOR: Maddaly Ravi Sri Ramachandra University . Water bath The water should be checked constantly for the level and quality.

SOP on Media Preparation - Pharmaceutical Guidance

SOP on Media PreparationObjective: To lay down the procedure for Preparation of Media. Scope: This SOP is applicable for preparation of sterile media used in Microbiology Laboratory of (Pharmaceutical Company Name). Responsibility: Microbiologist or above of Microbiology Laboratory. Head – Microbiology section. Accountability: Head – Quality Control Head – Quality Assurance.

ESC, Ft. Meade, MD Standard Operating Procedure

SOP No. EQ-02-03 Date Revised 04-25-05 Page 3 of 6 7.4 Thermometers used to measure the temperature of water baths, incubators, refrigerators, and freezers, including FRIO-Temp Precision Thermometers (H-B

STANDARD OPERATING PROCEDURE FOR .

This Standard Operating Protocol (SOP) manual is a guideline intended to assist as a reference material for routine laboratory activities in mycobacteriology lab. This guideline clearly spells out what is expected and required of personnel while handling mycobacteria during their day-to-day activities in the laboratory. SOPs provide a

Calibration of temperature control and monitoring devices

Standard Operating Procedure (SOP): A set of instructions having the force of a . nationally or internationally accredited calibration laboratory, using the "ice-water" procedure and it outlines the limitations of this approach. . prove the functionality and stability of the ice-water bath. c. During extended testing periods enough ice .

Operation, Calibration, Cleaning and Maintenance of .

This SOP is applicable for Operation, Calibration, Cleaning and Maintenance of bacteriological Incubator in Microbiology lab (Pharmaceutical Company Name). Responsibility Microbiologist or above of Microbiology Laboratory: Preparation of SOP.

CLSI Guideline for Clinical Laboratory Reagent Water .

May 18, 2016 · Clinical Laboratory Reagent Water can now be used in place of Type I and II water for most applications. Autoclave and wash water will generally be a satisfactory replacement for Type III water. 2. Total Organic Carbon (TOC) parameter has been added. Perhaps the most significant change of this guideline is the addition of the TOC parameter.

STANDARD OPERATING PROCEDURE FOR VARIOUS .

to standard operating procedure (SOP) and using personal protective equipment (PPE) where applicable. The use of UV in the laboratory is governed by „The control of Artificial Optical Radiation at Work Regulations 2010‟ UV light emitted from a transilluminator .

Antibodies & Protein Biology - Lab Equipment and Lab Supplies

The Corning LSE Digital Water Bath is a personal-sized bath with seamless chamber that can accommodate up to 6L of water or can serve as dry bath when using thermal beads. Pricing & .

Water Baths | Thermo Fisher Scientific - US

Our microprocessor-controlled Thermo Scientific water baths provide superior temperature uniformity for your specific applications and offer unique features such as a seamless-stainless steel interior chamber and epoxy-coated exterior which make .

T10-001A Care and maintenance of water baths

Bath water For the Stuart baths we recommend water, preferably distilled or deionised, with neutral pH. Ultra pure deionised or RO water with a resistivity >1Mohm should not be used, as this can leach the iron from the stainless steel and lead to corrosion. If necessary, add a little tap water to the pure water in the bath.

Procedure for operation of water bath

1.1 to lay down the procedure for operation of water bath, (neolab). equipment identification no: xxxxx. 2.0 scope. 2.1 this sop covers the operation procedure of water bath. 3.0 responsibility . 3.1 microbiologist. 3.0 accountability . 4.1 head - quality control. 5.0 procedure

Blog Teknik Laboratorium: SOP menggunakan Water Bath

SOP menggunakan Water Bath Waterbath - Penangas Air. Pengertian : . Water bath menggunakan daya listrik yang rendah sehingga sangat ekonomis dan efisien. Secara sederhana alat ini menggunakan pemanas pada air yang dipanaskan dengan api maupun dengan listrik atau uap dari air.

Installation and Operation Manual

3.05 The interior of the bath is constructed of stainless steel and is designed for operation with distilled water or water solutions, such as water ethylene glycol with corrosion inhibitor's added. The body is made from galvanized steel and is painted for added protection. A gable cover is also provided with the bath.

Standard Operating Procedure: Glassware Cleaning

Standard Operating Procedure: Glassware Cleaning Using clean glassware is key to the success of a chemical reaction, and cleaning glassware is part of good lab citizenship. All members of the lab must contribute to this. . are present when putting frits in the acid or DI water baths.