Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

9 Important Things Gauges Can Tell You About Centrifugal Pumps

If the Total Dynamic Head (TDH) is too high, the discharge gauge will read high. If the TDH is too low, the discharge gauge will read low. If you have a plugged suction line, the vacuum gauge reads very high. If you need an air release valve on a self-priming pump, the discharge gauge will show pressure before the pump comes to prime.

Understanding and avoiding pump cavitation | Flow Control .

High discharge pressure prevents fluid from easily flowing out, which leads to recirculation of fluid within the pump. The liquid gets stuck in a pattern of high-speed flow between the impeller and the housing, creating a vacuum effect that forms bubbles near the housing wall.

How to Operate and Maintain Your Liquid Ring Vacuum Pump .

Recommended Approach to Liquid Ring Vacuum Pump Maintenance. Liquid-ring vacuum pumps are built for long-lasting, high powered performances and can generally withstand a range of pressure levels. That said, a vacuum pump does have its limit. Behavior traits that seem out of the ordinary could easily be indicative of developing troubles inside.

Working Flow Rate: How to Compare Vacuum Pumps .

Featured Article Please check out our Diaphragm Vacuum Pump Systems section to find manufacturers that sell these products Diaphragm vacuum pumps with flow paths constructed of fluoropolymers like PTFE (e.g., Teflon ®, DuPont, Wilmington, DE) offer tremendous advantages for laboratories.Compared with the use of traditional oil-sealed rotary vane pumps for moving corrosive vapors, oil-free .

ROTARY (VANE) VACUUM PUMP

of the pump at increased pressure, flowing out through the diffusion pump outlet, where they are compressed to ambient pressure by the secondary mechanical forepump and exhausted. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump is typically used to maintain an outlet pressure around 0.1 mbar.

Oil discharge from vacuum pump exhaust - possible causes .

Oil discharge from vacuum pump exhaust – possible causes and remedies. . This will restrict the flow of air through the oil mist separator and increase the back pressure against the pump. The higher pressure will increase the work done by the pump and the motor and cause overheating. Severe contamination may cause the oil mist separator to .

Polymer discharge pumps - Customised products solutions

Suction pressure Vacuum up to max. 40 bar Transport pressure /differential pressure Up to 320 bar (4642 psig). The values listed are standard values and must not coincide under certain circumstances. Others values are available upon requests. Pump sizes From 4.7-22-22 (4.7 ccm/rev – 10 kg/h) to 25,000-360-360 (25,000 ccm/rev – 52,000 kg/h).

Vacuum Pump Discharge & Air / Oil Separation

Vacuum Pump Discharge & Air / Oil Separation. Oil mist exhaust filters capture oil fog, mist or smoke from the discharge of vacuum pumps. The EE and EF series designed for laboratory and medical vacuum pumps, these compact oil mist eliminators offer the option of a back pressure relief valve to evacuate collected contaminates.

Vacuum Pump Discharge & Air / Oil Separation

Vacuum Pump Discharge & Air / Oil Separation. Oil mist exhaust filters capture oil fog, mist or smoke from the discharge of vacuum pumps. The EE and EF series designed for laboratory and medical vacuum pumps, these compact oil mist eliminators offer the option of a back pressure relief valve to evacuate collected contaminates.

What is Vapor Pressure and How does it Impact Pump .

May 14, 2014 · Pumps work by creating an area of very low pressure near the inlet of the pump. Some pumps, like the Quattroflow quarternary diaphragm pump, will even suck and pump air. If the pump pressure at the inlet of the pump drops below the fluids vapor pressure, the fluid will flash off.

Vane Pumps - Pump School

Vane pumps are noted for their dry priming, ease of maintenance, and good suction characteristics over the life of the pump. Moreover, vanes can usually handle fluid temperatures from -32 C / -25 F to 260 C / 500 F and differential pressures to 15 BAR / 200 PSI (higher for hydraulic vane pumps).

: pump discharge hose

JGB Enterprises A008-0321-1625 Eagle Red PVC Discharge Hose, 2" x 25', Male x Water Shank Couplings, 150 psi Working Pressure, -14 Degree F to 170 Degree F .

Succeed at Vacuum System TROUBLESHOOTING

Excessive pump discharge or backpressure. A vacuum pump is designed to discharge to at-mospheric pressure or just slightly above unless the manufacturer specifically designates it as a compressor. As the discharge pressure of the pump increases above atmospheric pressure, this raises the differential pressure across the pump, resulting in .

Vectra SX Pump & Compressor Series | NASH Liquid Ring

Operates as a vacuum pump and compressor with a discharge pressure range of 33 psia (2.3 bar abs.) Some applications require vacuum and compression in one process. Instead of handling the gas with two separate machines, our liquid ring vacuum pump and compressor models can do the job with only one pump - reducing cost and simplifying .

Vacuum Pump Separator/Silencers - VANEC

Vacuum systems using liquid ring vacuum pumps are typically closed-loop on the suction side of the pump and discharge to atmosphere on the outlet side of the pump. The size of the separator/silencer is dependent on the inlet gas flow in ACFM, and the seal fluid liquid load in GPM.

Pump & Motor Selector - Shipco® Pumps

Pump Discharge Pressure. psig. Display Pumps. 2. Vacuum Pressure & Air Capacity. Applies to vacuum units Type BVC, Type BVMC, Type SHVM and Type SHVC with Model V air pump. Air capacity for single units rated in CFM @ 70°F water temperature and referenced to a barometric pressure .

Rules to Follow to Avoid Pump Problems | Valin

A final note before discussing NPSH. Pressure for centrifugal pumps (inlet and outlet) is measured in Feet of Head and pressure for positive displacement pumps is typically measured in psi. One of the exceptions is for air operated diaphragm (AOD) pumps, which is a positive displacement pump where discharge pressure is measured in Feet of Head.

Fundamentals of Vacuum | Hydraulics & Pneumatics

Mechanical vacuum pumps. A conventional vacuum pump may be thought of as a compressor that operates with its intake below atmospheric pressure and the discharge at atmospheric pressure. Compressors and vacuum pumps have identical pumping mechanisms.

Common Pump Formula - MGNewell

= static discharge head h ft = pressure drop in discharge line p t > 0 for pressure p t < 0 for vacuum p t = 0 for open tank Total Suction Head H s = h s + h fs + (± p s) where: h s = static suction head > 0 for flooded section < 0 for flooded section h fs = pressure drop in suction line p s > 0 for pressure p s < 0 for vacuum p s = 0 for open .

What are the various ways to increase the suction pressure .

Jun 11, 2017 · The vacuum is created by vapor pressure of liquid in the system. but it does not restrict it when we use gas. For higher vacuum use we add multiple stages. For .

How to Gauge the Performance of Centrifugal Pumps

w When the vacuum gauge reads very high, you may have a plugged suction line. w The discharge gauge will show pressure before the pump comes to prime if you need an air release valve on self-priming pumps. w With a MAX VAC test, you will learn if the pump is pulling the proper vacuum on self-priming pumps.

Pump CALCULATIONS, Flow rate, RPM, Pressure, Power .

Jul 08, 2017 · In this video we learn how to calculate the pump performance curve vales for Volume flow rate, RPM, Head pressure, pump power, impeller diameter for centrifugal pump. This can be applied to pumps .

Two Stage Liquid Ring Vacuum Pump - Principles of .

This increases the pressure until discharge takes place through the discharge port. A continuous flow of fresh sealing liquid is supplied to the pump via the sealing-liquid inlet. In the case of the two-stage liquid ring pump, the discharge from the first stage does not discharge to atmosphere.

How to Operate and Maintain Your Liquid Ring Vacuum Pump .

Recommended Approach to Liquid Ring Vacuum Pump Maintenance. Liquid-ring vacuum pumps are built for long-lasting, high powered performances and can generally withstand a range of pressure levels. That said, a vacuum pump does have its limit. Behavior traits that seem out of the ordinary could easily be indicative of developing troubles inside.

Blower Silencers, Vacuum Pump Silencers | pdblowers, Inc.

A pressure pulse is created each time this occurs. This pressure pulse creates noise and vibration. Blower silencers can be used to reduce this noise and vibration. Silencers are typically used on the inlet and discharge of a positive displacement blower used for pressure applications. A discharge silencer is typically used on a vacuum application.

Low Pressure Compressors | NASH Liquid Ring Technology

Low pressure liquid ring compressors deliver reliable, proven performance for wastewater treatment, digester gas compression, aeration, and many other applications and industries. With a discharge pressure up to 30 psig (3 bar), Nash offers efficient, low pressure compressors with .

Benefits of Vacuum Pump Systems | Pumps & Systems

Since the vacuum pump will not tolerate back pressure, the discharge manifold and discharge pipe centerline should be level or below the center of the inlet flange of the discharge separator. The discharge gas and seal water separator open to the atmosphere separator is not considered a pressure vessel since it discharges to the atmosphere.

Pumping Condensate from Vented Receivers | Spirax Sarco

Vented pumps, pumping traps and pump-trap installations. Discharge lines from pumps vented to atmosphere are sized on the discharge rate of the pump. Condensate passing through pumping traps and pump-trap combinations in closed loop applications will often be at higher pressures and temperatures and flash steam will be formed in the discharge line.

Control the Flow of a Pump - Precision Back Pressure .

There are several methods to control the flow of a pump. One method is to ensure the pump always meets its minimum flow requirements by setting up a recirculation loop from the reservoir, also called a bypass line, equipped with a pressure bypass valve.When the process demand is low, the pump output will still meet the minimum flow requirements.

How to Calculate the Suction Pressure of a Pump | Sciencing

Operating pumps move fluids in piping systems by creating a low suction pressure at the inlet side and a high discharge pressure at the outlet side. You can calculate suction pressure expressed in feet for a water distribution system in the "United States Customary System Units" using suction pressure .