Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Extraction and Washing Guide - MIT OpenCourseWare

paper and a large funnel (or the Büchner method). To guard against bumping on the rotovap, do not fill the flask more than half full. 10) Concentrate the solution on the rotovap then dissolve the compound in a small amount of solvent and transfer to a small pre-weighed (tared) flask. 11) Concentrate the solution on the rotovap again.

Organic Chem 2 LAB Flashcards | Quizlet

What do you do if a solution is NOT drying in the rotovap? Add cold pentane. Purpose of Wittig Reaction. To convert 9-anthraldehyde into Trans-9-(2-penylethenyl) anthracene by adding phosphorus ylide and see stereochem through NMR. Reactants of Wittig.

Getting the green and waxes out afterwards | THCFarmer .

Feb 12, 2012 · Not an unexpected taste treat, because as many of ya'll know, lighter fluid is in point of fact light naphtha, which is a blend of pentane (5 carbon atom chain) and hexane (6 carbon atom chain). Most of skunk pharm oil goes into oral or topical medications, though some is vaporized.

How would you separate a mixture of benzoic acid, phenol .

All three compounds dissolve in organic solvents (like dichloromethane or diethyl ether) better than in water. However, benzoic acid is the most acidic compound among them, it can react with bicarbonate ion. Phenol is less acidic than benzoic acid.

Research - Liu Lab on Energy Conversion and Catalysis (L2EC)

The third theme in our group is directed on the development of well-defined molecular catalysts based on inexpensive metals (e.g. Mn, Fe, Ni, Co, W, Mo) to handle homogenous catalysis that is traditionally achieved by precious metal (e.g. Rh, Ir, and Pd) based catalysts. To realize "base metals for noble tasks", we pay particular attention to ligand design and take fully advantage of the .

Chem 331L Final Flashcards | Quizlet

Start studying Chem 331L Final. Learn vocabulary, terms, and more with flashcards, games, and other study tools.

How to use a Rotary Evaporator

3. A metal or Keck clip is used to secure the flask and the bump trap. The green one shown below fits 24/40 ground glass joints. Similar blue clips fit 19/22 joints and the yellow ones fit 14/20 joints, which will most likely used in the lab.

How to extract essential oils from petals, leaves and .

Pentane is filled into the flask. The amount should be four to five times the volume that fits into the extractor. Heat the solvent so that it boils and keep it refluxing at the condenser until the extractor has discharged the solution that forms at least three times into the flask.

Solvent Boiling Points Chart

Solvent Boiling Points Chart (all boiling points at standard pressure) Solvent Boiling Point (°C) Solvent Boiling Point (°C) Acetic Acid 118.0 Ethyl Acetate 77.1 Acetic Acid Anhydride 139.0 Ethyl Ether 34.6 Acetone 56.3 Ethylene Dichloride 83.5 Acetonitrile 81.6 Ethylene Glycol 197.5 Benzene 80.1 Heptane 98.4 iso-Butanol 107.7 n-Hexane 68.7 n-Butanol 117.7 Hydrochloric Acid 84.8 tert-Butanol .

Pyridine Is miscible with EVERYTHING!? : chemistry

Really need some help; need to do an extraction from Pyridine so obviously I need a non miscible solvent but pyridine seems to be compatible with nearly all solvents, .

The Overall Reaction: OH NaBHA Or ЕТОН Benzoin Pro .

Transfer the dried organic layer to a dry (tared) round-bottom flask and ask the TA to show you how to evaporate the solvent using the rotary evaporator (also call the rotovap). Once the solvent is removed, add a few milliliters of ice-cold pentane and evaporate the pentane using the rotovap.

CHEM 213 Experiment 5: Distillations Post-Lab

a. What is the boiling point of a mixture of 60% hexane and 40% pentane? b. What are the constituents of the vapor above this solution? c. How many theoretical plates are necessary to give practically pure pentane at the start of a distillation? 3. Consider your fractional distillation. a. What was the purpose of adding the packing material? b.

A Trick to Fluorinate Grignards - Drug Hunter

Jun 02, 2018 · A 50 mL Schlenk flask under N2 was charged with 3,5-dibromopyridine ([B], 1.21 g, 5.0 mmol) in THF (5.0 mL).i-PrMgCl·LiCl (5.5 mmol) in THF (1.16M, 4.7 mL) was added at 0°C and the mixture was stirred at this temperature for 1 h.Then the solvent was removed in vacuo (0.5 mbar, 40°C, 0.5 h). CH2Cl2 (5 mL) was added, and NFSI (1.95 g, 6.0 mmol) in CH2Cl2 (15 mL) and .

Ultimate Cannabis Extraction Guide | Precision Blog

15L/h recovery rate with 50L UL listed rotovap; 2.25H processing time per run (single batch with full recovery) 3H processing time (triple batch with full recovery) Rated for low temp conditions (-40C or below recommended) 8-15lbs per batch capacity (see yield .

The MSDS HyperGlossary: Evaporation Rate

Safety Data Sheets: An evaporation rate is the rate at which a material will vaporize (evaporate, change from liquid to vapor) compared to the rate of vaporization of a specific known material. This quantity is a ratio, therefore it is unitless. General usage: The mass of material that evaporates from a surface per unit time (examples: 3 grams per square meter per hour, 1 inch per acre per month).

Rotary evaporator - Wikipedia

A rotary evaporator (or rotavap /rotovap) is a device used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation.When referenced in the chemistry research literature, description of the use of this technique and equipment may include the phrase "rotary evaporator", though use is often rather signaled by other language (e.g., "the sample was .

Operation Manual Rotavapor R 210/215 - Marshall Scientific

Pentane C 5 H 12 72.1 381 36 06.26 atmospheric n-propylalcohol C 3 H 8 O 60.1 787 97 0.804 67 Pentachloroethane C 2 HCl 5 202.3 201 162 1.680 13 1,1,2,2-tetra-chloroethane C 2 H 2 Cl 4 167.9 247 146 1.595 20 Tetrachlorocarbon CCl 4 153.8 226 77 1.594 271 1,1,1-trichloroethane C 2 H 3 Cl 3 133.4 251 74 1.339 300 Tetra-chloro-ethylene C 2 Cl 4 .

Supplementary Information: H Production Mediated by CO via .

through celite, and the solvent was removed on a rotovap. Pentane (100 mL) was added to the resulting yellow oil and the product was sonicated for 30 minutes, which resulted in a white solid that was collected on a medium porosity frit and washed with pentane. Yield: 5.65 g (74%). 1H NMR (300 MHz, CDCl

Advanced Refinement Techniques - Cannabis Alchemy

Advanced Refinement Techniques Cannabis Alchemy. by D.Gold. The translucent amber oil produced by charcoal filtering the ether phase of the extraction and isomerizing the cannabidiol present to THC contains, in most cases, between thirty and sixty per cent THC.

Title: Rotary Evaporator Page 1 of 6 ROTARY EVAPORATOR

Pentane 109-66-0 35 -49 IA 0, 4, 0 aquatic tox., extremely flammable Heptane 142-82-5 98 -4 IB 2, 3, 0 very toxic to aquatic life . ☐Note placed in front of the rotovap to indicate to others what chemicals are being used. ☐Solvent trap is emptied and bump trap is cleaned prior to use.

Methyl Migration to Coordinated CO

THF is removed on the rotovap to afford the crude product. 2nd Lab Period Part A: Preparation of Cyclopentadienylmethyliron dicarbonyl (5) continued. Extract the crude product with pentane and filter. Rotovap the resulting orange solution to afford solid compound 5. Product Characterization: Record the 1H NMR spectrum of 5 in CDCl

How would you separate a mixture of benzoic acid, phenol .

All three compounds dissolve in organic solvents (like dichloromethane or diethyl ether) better than in water. However, benzoic acid is the most acidic compound among them, it can react with bicarbonate ion. Phenol is less acidic than benzoic acid.

CHEM 213 Technique Experiments

CHEM 213 Technique Experiments Experiment 7: Column Chromatography Number of labs - one Reactions performed – None Chemicals used: Fluorene-fluorenone mixture, hexanes, methylene chloride, silica gel Supplies needed: Various sized beakers, chromatography column Techniques: Column chromatography, rotovap Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, .

Hexane Honey Oil | Skunk Pharm Research

Mar 15, 2012 · Pentane, with five carbons in the chain, is the first completely insoluble alkane. It's longer chain gives it a higher specific gravity and higher boiling point than butane. Hexane boils at 69C/156.2F, versus -0.6C/30.9F for butane, which makes it more difficult to purge.

Home | Environmental Health & Safety | UCI

It is a good idea to cool the receiving flask (e.x. solvent reservoir); it prevents any solvent from evaporating from the receiving flask, especially for low boiling solvents (e.g. pentane). Connect the bump trap to the rotovap and secure with the metal clip or a keck clip depending on the model of rotovap (pictured below).

Solvent Removal - Organic Chemistry

The motor in the rotovap turns the flask rapidly, providing a greater surface from which evaporation can occur and speeding up the process. Cooling coils in the rotovap condense the vapors and drop them into a collection flask so that they can be recycled or properly disposed. The roto-vap is connected to a vacuum source, and again, this speeds .

Pyridine Is miscible with EVERYTHING!? : chemistry

Really need some help; need to do an extraction from Pyridine so obviously I need a non miscible solvent but pyridine seems to be compatible with nearly all solvents, .

Extraction and Washing Guide - MIT OpenCourseWare

paper and a large funnel (or the Büchner method). To guard against bumping on the rotovap, do not fill the flask more than half full. 10) Concentrate the solution on the rotovap then dissolve the compound in a small amount of solvent and transfer to a small pre-weighed (tared) flask. 11) Concentrate the solution on the rotovap again.

Future4200

The Future Is Now. In order to advertise your hemp products on this site, you must follow these directions: You will need to provide me samples (1g or a single unit) with COAs of any products you wish to advertise on this site.

Rotary evaporator - Wikipedia

A rotary evaporator (or rotavap / rotovap) is a device used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation.