Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Laser Chiller Air Cooling Industrial Low Temperature Water .

Chiller, Air Cooled Chiller, Mini Chiller manufacturer / supplier in China, offering Laser Chiller Air Cooling Industrial Low Temperature Water Chiller Food Pharmaceutical Stainless Steel Pump Dehumidification Chiller 1HP, Small Water Cooled Chiller Unit Ice Water Cooling machine Portable Cooling System, 5tr Water Cooled Chiller Match with Cooling Tower for Plastic Molding Machine and .

High Efficiency Chiller | SMC Corporation of America

HRSH Water-cooled recirculating chillers offer a cooling capacity range of 11.5 to 24 kW. Coolant and refrigeration circuits are included in a compact and lightweight package. Extracted heat is water cooled. An inverter provides demand-based rotation control for the compressor, pump and fan (air cooled model), offering substantial energy savings.

chiller -10℃

air cooled low temperature chillers supply ndustrial key links -5 ℃, -10 ℃ and other low-temperature refrigerant (ethylene glycol or brine water) medium, to provide continuous chilled water.

Degrading Chilled Water Plant Delta-T: Causes and Mitigation

secondary pumps, another primary chilled water pump and chiller are started. A pump and chiller are shut off when flow in the common leg exceeds that of one pump, with some addi-tional margin to prevent short cycling. The load-based strategy measures system load or indirect indications of load such as return water temperature. Chillers

Air Cooled Screw Heat Pump | Products | Air Solution .

It is a system that supplies high temperature water up to 80℃ by using 70-80% of unused energy such as waste heat source, river water and ground water discharged from power plants and sewage treatment plants. It can save energy economically because it draws low temperature heat energy to high temperature heat energy with small amount of energy.

CryoDax Low Temperature Liquid Chiller Systems - Mydax Inc.

Like all Mydax chiller systems, our CryoDax low temperature liquid chiller systems utilize our Advanced Temperature Control Technology 0 to proportional cooling and heating control, rugged tubular steel frames and touchscreen controls along with leak free pumps.

Centrifugal Water Pumps | ChillXChillers.com

An often underappreciated component of water cooled systems is the pump; the literal heart of your cooling system! Centrifugal pumps are the best option for water cooled applications for several reasons, but namely: relatively low head is required which centrifugal pumps .

LOW TEMPERATURE CHILLERS - Low Temp — Drake Chillers

Whether you need calcium chloride chilled to -29°F or fuel chilled to -22°F we are here to help you complete that task. Many chiller companies do not want to work with the complexity of low-temp chillers. However, we understand the many challenges of low temp chilling, including the impact of fluid viscosity, pump selection, oil flow .

Usa Low Temperature Circulating Water Cool Lab Chiller .

3L low temperature recirculating cooling chiller. The HAOCHENG coolant pump are designed to provide a continuous supply of fluid at a constant temperature and volume. This unit offers a refrigeration system, heat exchanger, imported recirculating pump, 1Cr18Ni9Ti reservoir, and a microprocessor temperature controller. These pump offer the following features:

Air cooled chiller; Water cooled chiller; Low temperature .

Jiangsu POTEN Refrigeration Equipment CO.,Ltd. is a Sino-Hongkong joint venture establish in 2007, which has been focusing on the research & development, production and sales of industrial refrigeration equipment. welcome to import high quality 【Chiller】 from【Jiangsu POTEN Refrigeration Equipment CO.,Ltd., [email protected]

chiller 2℃

air cooled low temperature chillers supply ndustrial key links -5 ℃, -10 ℃ and other low-temperature refrigerant (ethylene glycol or brine water) medium, to provide continuous chilled water.

Ultra Low Temperatures Chillers

Stand alone Air Cooled Chillers with intergrated pump and tank systems designed to provide ultra low fluid temperture. (-40°C, -60°C, -80°C and -120°C) This style/model of chiller removes heat from the fluid being cooled and transfers it to the surrounding ambient air.

The Ultimate Guide to Chiller Systems. Everything You Need .

Chillers provide a continuous flow of coolant to the cold side of a process water system at a desired temperature of about 50°F (10°C). The coolant is then pumped through the process, extracting heat out of one area of a facility (e.g., machinery, process equipment, etc.) as it flows back to the return side of the process water system.

Air Cooled Screw Heat Pump | Products | Air Solution .

It is a system that supplies high temperature water up to 80℃ by using 70-80% of unused energy such as waste heat source, river water and ground water discharged from power plants and sewage treatment plants. It can save energy economically because it draws low temperature heat energy to high temperature heat energy with small amount of energy.

Water-Cooled Chillers | Carrier Commercial Systems North .

With a wide range of water-cooled chiller types (scroll, screw, and centrifugal), capacities (16 to 5,500 Tons) and sustainable refrigerant options, Carrier is a leader in the industry. Whether it be non-ozone depleting refrigerant, simple or modular installation, superior efficiency and powerful controls, these chillers are ideal for both replacement and new construction projects.

Chilled Water Pumps, Systems and Tank Sets For Process Cooling

Apr 05, 2018 · An industrial pump tank set is basically a large reservoir holding the chilled or tower water. Each tank will have one or more chiller/tower pumps used to circulate the hot process return water to the chiller(s) or cooling tower(s), and one or more industrial pumps to circulate the cooled water to the process equipment.

RKS J Compact Chiller With Water Tank (Air Cooled) | ORION .

The ORION Machinery RKS-J Series compact chiller with built-in water tank offers ease of use + convenience + value. ±2.0 ℃ temperature control is possible with compressor ON/OFF control making it an outstanding general purpose chiller. This model also has a high pressure pump .

China Low Temperature Coolant Circulation Chiller Pump .

Cooling Chiller, Water Chiller, Water Cool Chiller manufacturer / supplier in China, offering Low Temperature Coolant Circulation Chiller Pump, Vacuum Filter for Laboratory Suction Filtration, Glass Vacuum Filter Vacuum Suction Filtration 10L and so on.

Chiller Fault Finding - The Engineering Mindset

Jul 02, 2019 · Low suction pressure could also be caused by the condenser water temperature being too low. So you want to have a look at the set points and the design criteria for that. You might have to adjust the bypass valves around the cooling towers to make sure that the waters coming back at the correct temperature.

Low Temperature Test Chillers-Air & Water Cooled

Low Temperature Test Chillers-Air & Water Cooled . D004879AA OTT Series Low Temperature Chiller Un Priced 1 . OTT Series – Low Temperature Models OTT 3 kW to 9 kW . A Partial List of Process Cooling Applications : Laboratory. Air or Water Cooled . .

Ultra Low Temperatures Chillers

Stand alone Air Cooled Chillers with intergrated pump and tank systems designed to provide ultra low fluid temperture. (-40°C, -60°C, -80°C and -120°C) This style/model of chiller removes heat from the fluid being cooled and transfers it to the surrounding ambient air.

Low temperature water chillers | OMI Srl

Low temperature water chillers Designed to meet the needs of the chemical and food industries. Oil chillers Dedicated to the sector of remote control machinery or those with hydraulic cooling. Air to water coolers Equipped with pump and tank, suitable for various industrial applications.

GalxC Cooling | Products | GalxC.co.uk

GalxC offers a high quality range of chillers designed and built for air conditioning applications including HVAC chillers, glycol chillers, chiller heat pumps, multi-pipe chillers, small footprint chillers, low noise chillers, energy efficient chillers for energy saving, hydrocarbon R290 chillers and water cooled chillers and remote condenser chillers which can be supplied with remote .

Grumman/Butkus Associates

Pump energy is increased because greater flow is required. Assuming a 10˚F design chilled water temperature difference (e.g., 44˚F supply water temperature and a 54˚F return water temperature), there is about an 11% increase in flow rate for a 1˚F drop in return water temperature .

Usa Low Temperature Circulating Water Cool Lab Chiller .

3L low temperature recirculating cooling chiller. The HAOCHENG coolant pump are designed to provide a continuous supply of fluid at a constant temperature and volume. This unit offers a refrigeration system, heat exchanger, imported recirculating pump, 1Cr18Ni9Ti reservoir, and a microprocessor temperature controller. These pump offer the following features:

Design Temperature Difference for Chillers - HVAC School

Nov 13, 2018 · The chiller will always try to maintain at 44°f(6.66°C) chilled water out (or whatever the setpoint is) as long as it can do so. The refrigeration cycle doesn't change, stick to the basics and don't over think it. When running building, try to get your condenser water as low as possible when running. But stay above 65°F(18.33°C).

Medium/Low Temperature Water-Cooled Water Chiller - Buy .

Withair® the medium and low temperature chiller is based on this year's design of low temperature water-cooled chillers by key technicians of this company. It integrates the advanced technology of products in same category, and is a highly effective, energy saving and environment protecting fifth generation chiller designed and developed by .

Troubleshooting Chilled Water Systems

A guide to use when sizing a chilled water system is to figure the total pump head will be around 60- to 70-ft pump head. When I see pumps heads closing in at 100 ft - or worse yet, 200 ft - I'm pretty sure I will find a lot of balancing valves substantially closed or maybe just one substantially closed balancing valve on the pump discharge.

CryoDax Low Temperature Liquid Chiller Systems - Mydax Inc.

Like all Mydax chiller systems, our CryoDax low temperature liquid chiller systems utilize our Advanced Temperature Control Technology 0 to proportional cooling and heating control, rugged tubular steel frames and touchscreen controls along with leak free pumps.

Chiller - Wikipedia

Industrial chillers typically come as complete, packaged, closed-loop systems, including the chiller unit, condenser, and pump station with recirculating pump, expansion valve, no-flow shutdown, internal cold water control. The internal tank helps maintain cold water temperature and prevents temperature spikes from occurring.