Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Home | Environmental Health & Safety | UCI

Must read, sign, understand, and follow this SOP when using the rotary evaporator . Must read the safety data sheet (SDS) for any compound that is being used as the mobile phase or as the sample for HPLC. Definitions. In this section, define any acronyms or abbreviations that are used in the procedure.

Laboratory Specific Standard Operating Procedures

Laboratory Specific Standard Operating Procedures Oregon State University Remcho Research Group 296 Linus Pauling Science Center Corvallis, OR 97331 Please complete this form, save and add to the group WIKI, and print print a hard copy for the Laboratory Chemical Hygiene Plan (LCHP) after review by the PI. Date: Principal Investigator:

Home | Environmental Health & Safety | UCI

A rotary evaporator (rotovap) is a fast and effective method of removing solvent from a flask. A rotovap removes solvent by reducing the pressure within the flask using a vacuum, rotating the sample to increase its effective surface area, and heating the solution.

Heidolph Instruments : Operation Manuals

Rotary Evaporators Large-Scale Rotary Evaporators Automatic Module - Distimatic Magnetic Stirrer Overhead Stirrers Shakers & Mixers Peristaltic Pumps . Company . .

Downloads - IKA VACSTAR control

Separation Rotary Evaporators Centrifuges Reactor Systems Laboratory Reactors Photo Bioreactors Vacuum Technology Vacuum Liquid handling Pipettes Controlling & Measuring Laboratory Software Calorimetry Calorimeters Decomposition Systems Microwave Chemistry Microwave Synthesizer

USA Lab 50L Rotary Evaporator Rotovap RE-1050 - 180°C .

The USA Lab 50L RE Series rotary evaporator recovers solvents efficiently and fast.This unit provides consistent and repeatable results at an affordable price.With GG-17 High Borosilicate Glass, all pieces have been designed for efficient use of surface area. This means faster recovery without compromising quality.Our evaporators come standard with safety features such as over-temperature shut .

เครื่องกลั่นระเหยสารแบบหมุน Rotary evaporator

IKA RV8 เครื่องกลั่นระเหยสารแบบหมุน Rotary Evaporator 250,000.00 THB 350,000.00 THB (-29%)

analytical_instrument_support - Remcho Research Group Wiki .

SOP: SOP Yamato Rotary Evaporator RE300 . Oven Manuals & Standard Operating Procedures. Manual: Fisher Scientific Isotemp Oven - Model 625G. SOP: SOP Fisher Isotemp Oven. Manual: Shel Lab Vacuum Oven - Model 1425. SOP: SOP Shel Lab Vacuum Oven. Manual: Thermo Electron Precision Oven - Model 6524.

Standard Operating Procedure - UCSB

the reaction vessel to the rotary evaporator. Chloroform has to be disposed as hazardous waste in the appropriate container, which has to be kept closed. NOTE: Any deviation from this SOP requires approval from PI. Documentation of Training (signature of all users is required)

Thermal Evaporator: Standard Operating Procedure

This evaporator is used with many different materials; wear a respirator and gloves when the Chamber is open. 1. Vent the Chamber using the (air . (rotary pump) is off, the (roughing valve) is closed, the (backing valve) is open, the (Water In) and (Water Out) valves are closed, all satellite equipment are off, and the pressure in the Chamber .

Standard Operating Procedure: Rotovaps

signs of vigorous evaporation/bubbling are observed full direct vacuum can be applied. After all solvent is removed, SLOWLY open the vacuum release valve and run the pump open to the atmosphere for 60 seconds to purge the pump from any solvent prior to turning off the pump (if using the belt drive pump, .

Rotary Evaporators | Thermo Fisher Scientific New Zealand

IKA Rotary Evaporators. IKA's new RV 10 rotary evaporators for optimal distilling prove: Even one of the oldest chemical processes has room for improvement. For example, all IKA rotary evaporators are equipped with a motorised lift, which lifts the evaporator flask out .

Rotary Evaporators | Fisher Scientific

Rotary Evaporators; Rotary Evaporators 1 – 30 1132 . Interest Areas. Life Science; Chemicals; Chromatography; Industries; Fisherbrand; Outlet Corner; Events and Exhibitions. The Story of Science World; Activate Science; On-Site Exhibitions; Trade Shows; .

HEIDOLPH HEI-VAP OPERATING MANUAL Pdf Download | .

Page 1 Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership Operating Manual Page 2 Rotary Evaporator Hei-VAP Precision Operating manual must be read before initial start-up. Please follow the safety instructions provided. Please keep for future reference. Original-Betriebsanleitung Page 82 Rotationsverdampfer Hei-VAP Precision Betriebsanleitung vor .

SOP: Glassware Under Vacuum | PennEHRS

Rotary Evaporators Rotary evaporators (rotovaps) must be shielded to protect operators from risk of glassware implosion. When a rotovap is not contained in a fume hood or similar enclosure, the glass components must be plastic-coated or wrapped in friction tape .

HEIDOLPH HEI-VAP OPERATING MANUAL Pdf Download | .

Page 1 Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership Operating Manual Page 2 Rotary Evaporator Hei-VAP Precision Operating manual must be read before initial start-up. Please follow the safety instructions provided. Please keep for future reference. Original-Betriebsanleitung Page 82 Rotationsverdampfer Hei-VAP Precision Betriebsanleitung vor .

Home | Environmental Health & Safety | UCI

A rotary evaporator (rotovap) is a fast and effective method of removing solvent from a flask. A rotovap removes solvent by reducing the pressure within the flask using a vacuum, rotating the sample to increase its effective surface area, and heating the solution.

Ai SolventVap SE130 Rotary Evaporator | Rotovaps.net

Rotary evaporator features a specially designed motor and worm gear, which provides constant rotation at speeds from 10 to 180 rpm. As the flask containing the solvent is rotated, it continually transfers a thin layer of liquid over the entire inner surface. This gives a very large surface area for evaporation, which is caused by the gentle .

Rotary Evaporation to Remove Solvent | Protocol

Rotary evaporation is a technique commonly used in organic chemistry to remove a volatile solvent from a non-volatile compound of interest. Invented by Lyman C. Craig in 1950 the rotary evaporator, or rotovap, gently removes solvents from compounds using heat combined with reduced pressure to evaporate, dry, and purify samples for further downstream use.

School of Chemistry SOP For Operation Of Vacuum Pumps .

This SOP contains some basic guidelines on the use/set-up of vacuum systems, laboratory vacuum pumps and the necessary associated traps. Vacuum Pumps: Vacuum pumps are used in the lab to remove air and other vapours from a vessel or manifold. The most common uses are on rotary evaporators, reduced pressure distillations, drying manifolds,

Ethanol Solvent Recovery in Hemp or Cannabis Distillation .

The evaporation and condensation of solvents, such as ethanol, require a balanced amount of heat and cooling to make the recovery efficient and effective. The hemp and cannabis industry quickly turned to rotary evaporators, also known as a RotoVap. Basically, a RotoVap has a spinning flask that is in contact with heated water.

SOP Rotary Evaporator - Scribd

universitas jambi. fakultas sains dan teknologi laboratorium instrumen dan tugas akhir. prosedur no. berlaku sejak sop/lita/1/2015 revisi halaman : 1 dari 2 standard operating procedure (sop) penggunaan alat rotary evaporator nama alat. rotary evaporator. fungsi

Temperature control,rotary evaporator,glass reactor .

Rotary Evaporator 1L/2L R-1001VN/R-1001LN. Rotary Evaporator 1L/2L R-3001. Rotary Evaporator 20L R-1020. Lifting Glass Reactor 5L/10L/20L/30L/50L (GRL series) Water Circulating Vacuum Pump SHB-III/IIIA/IIIS . Recirculating Chiller DL-400. who? we areGreatwall.

Maryna R. - Separations Lab Technician - Toronto Research .

- Purification of synthetic organic compounds using flash chromatography (Buchi, Biotage), normal and reverse phase, including taking TLC's of fractions, combining, concentrating and drying them using rotary evaporator, freeze dryer and/or oil vacuum pump dryer - Method development using .

Standard Operating Procedure - Rotary Evaporator

Rotary Evaporator in the P.O.W.E.R. Laboratory Elliot Sepos, April 2012 Description of Process Some chemical procedures require a quick and effective separation of substances through evaporation. The Rotary Evaporator is a tool which puts the separable substance under vacuum and heats evenly through a spinning motion, causing one component to .

SOP STANDARD OPERATING PROCEDURE

14. Ensure speed dial is to zero and turn off motor switch the rotary evaporator. 15. If finished for the day turn off water bath and power points, and leave the rotary evaporator and work area in a safe, clean and tidy state. Section 4 – Spill Procedure and Waste Disposal 1. Consult SDS of specific chemical for spill procedure. 2.

Ai UL/CSA SolventVap 2.6-Gallon/10L Rotary Evaporator w .

A rotary evaporator is a device used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation. The process of rotary evaporation is most often used to separate solvents with low boiling points, such a n-hexane or ethyl acetate, from compounds which are solid at room temperature and pressure.

USA Lab 50L Rotary Evaporator Rotovap RE-1050 - 180°C .

The USA Lab 50L RE Series rotary evaporator recovers solvents efficiently and fast.This unit provides consistent and repeatable results at an affordable price.With GG-17 High Borosilicate Glass, all pieces have been designed for efficient use of surface area. This means faster recovery without compromising quality.Our evaporators come standard with safety features such as over-temperature shut .

Temperature control,rotary evaporator,glass reactor .

Rotary Evaporator 1L/2L R-1001VN/R-1001LN. Rotary Evaporator 1L/2L R-3001. Rotary Evaporator 20L R-1020. Lifting Glass Reactor 5L/10L/20L/30L/50L (GRL series) Water Circulating Vacuum Pump SHB-III/IIIA/IIIS . Recirculating Chiller DL-400. who? we areGreatwall.

Falling Film Evaporator For Botanical Separation .

Delta Separations uses its innovative falling film evaporator for botanical separation and ethanol alcohol recovery from your extracted bio-mass tincture. The system maintains a high evaporation rate, which significantly increases the throughput of crude oil production, eliminating the need for multiple large rotary evaporator systems.