Scientific Lab Equipment, Pilot Plant Kilo Lab Units .

High Pressure Autoclaves . We manufacture a wide range of Bench Top Jacketed Autoclaves from 2L to 25L with M.O.C. consisting of SS 316, Hastelloy & Glass with pressure ranging from 5 bar to 100 bar (Depending on M.O.C.)

Glass Bottles Autoclavable at Thomas Scientific

.borosilicate glass, general purpose media bottles are autoclavable with permanent white imprinted graduations and marking spots. The screw thread opening has an ID of approximately 30mm. The supplied cap is liner-less and both the cap and drip free ring are polypropylene autoclavable to .

Kilolab reactor

This 50 liter reactor at kilo lab scale fits in the fumehood. The reactor system is completed with a Huber thermostat and is controlled with recipe software by Systag System Technik. Characteristics: 50 liter glass/glass lined reactor; With cooling and heating; Systag FlexyALR recipe software; Automatic dosing pH-measurement

Autoclaving Guidelines | Environmental Health and Safety

Autoclaving is the most effective and reliable means of sterilizing laboratory materials. Autoclaving sterilizes material using saturated steam under pressure ("moist heat"). Due to the use of pressure, steam and high temperatures, there is significant risk for injury, so it's important for individuals to be properly trained on operational procedures.

Magnetically sealed Glass Reactors up to 6 bar pressure

The glass autoclaves are corrosion resistant and ensure high resistance against various acids, while allowing visual process control and monitoring. Nano-Mag Technologies is a prominent manufacturer and supplier of Glass autoclaves. We manufacture glass reactors with high quality borosilicate glass having excellent physical and chemical properties.

Parr Instrument Company

Since its founding more than one hundred years ago, Parr Instrument Company has been engaged exclusively in the manufacture and sale of chemical reactors, pressure vessels, calorimeters, combustion vessels, and related equipment developed specifically for laboratory use.

High Pressure Stirred Autoclaves, Bench Top Jacketed .

The glass, stainless steel or Hastelloy reactors ensures high resistance against acids. Visual process control and monitoring is also possible under pressure by using Glass Reactor Vessels. Various low to high torque magnetic drives ensure efficient mixing and stirring low to high viscosity process media as well as excellent heat transfer.

High-End, New Jacketed Glass Reactors | Shop USALab

Our reactors feature an outer jacket with stellar liquid circulation capabilities, ranging in temperature from -80°C to 250°C. You can count on finding that perfect reactor for your laboratory needs. Having the proper jacket is key to maintaining the ideal temperature for the glass reactor.

Autoclave Use and Safety - Dartmouth College

• Expect the custodial staff to handle autoclave bags that are outside of the designated waste bins. They are not trained to handle biowaste. • Let autoclave bags accumulate in your lab, in the autoclave, or autoclave room. • Autoclave hazardous chemicals or radioisotopes. Contact EHS instead.

High Pressure Lab Autoclaves Reactors/reaction vessel .

Mar 20, 2018 · high pressure Lab reactor with the character of high temperature resistance, anti-corrosion and strong production capacity features. Wide range used for .

Laboratory Sharps Disposal | Environmental Health & Safety

Laboratory glass is defined as equipment generally made of pyrex, borosilicate, and quartz glass used for scientific experiments. Examples of laboratory glass include, but are not limited to, the following: beakers, flasks, graduated cylinders, stirring rods, test tubes, microscope slides, glass pipettes, glass petri dishes, and glass vials.

Stirred Autoclave Glass Reactor - Magna-Safe

Removable PTFE / Metal / Glass liners can be offered for autoclaves from 100 ml - 25 ltr. Theseliners can be used for reactions that are corrosive, to prevent the autoclave body from corrosion.PTFE & glass liners can be used upto 200°C & metal upto 500°C. The heat transfer is poor withPTFE & glass liners.

Laboratory Glassware | PYREX Lab Glassware | Corning

Exceptional strength and stability. Brilliant transparency. Superior resistance to chemicals, contaminants, and drastic changes in temperature. These are among the key properties that enable PYREX glass to endure even the toughest laboratory environments, making it the indispensable partner for chemists and research scientists for more than 100 .

Pressure vessel manufacturer | High pressure reactor

For the past 40 years, Amar Equipments Pvt. Ltd. has built its reputation on supplying high quality pressure reactors (ranging from 100 ltr to 2000 ltr), high pressure autoclaves (50 ml to 100 ltr), customized pressure vessels, fixed bed tubular reactors, fluidized bed reactor systems, packed bed tubular reactors, super critical fluid extraction units, Glass reactors, magnetic drives/couplings .

Lab Equipment Glass Autoclave Reactor 100L(id:10297923 .

Jacketed glass reactors are temperature and vacuum controlled instruments and pharmaceutical-grade mixing vessels with a 304 stainless steel reinforced PTFE agitator, capable of mixing and speeding up to 600 RPM.

Autoclave Equipment- Chemglass Life Sciences

You have no items in your shopping cart. Service Tools . My account; My Favorites; My Cart 0 ITEM(S); Checkout; Log in; Shopping cart 0 ITEM(S) >

Lab autoclave and reactor-The best lab furnace manufacturer

You are here:Home > Products > Lab autoclave and reactor > high pressure reactor. Model:CJF-2. hydrothermal synthesis reaction kettle. Model:HK-200. glass reactor. Model:GR-30L.

Buchiglas - miniclave steel

Laboratory pressure reactor system Reactor volume: 100 - 300 ml Pressure:-1 (FV) to +10 bar / 100 bar Temperature: -20 °C to +200 / 300 °C Material: Borosilicate glass 3.3, stainless steel, Hastelloy ®, PTFE Other materials, pressures & temperatures are available.

Autoclave Beakers at Thomas Scientific - Lab Supplies, Lab .

Plastic, with glass-like clarity, strong and impact-resistant Low form with spout Autoclavable Usable continuously to 150°C, intermittently to 175°C Excellent chemical resistance, although attacked by powerful oxidizing agents and affected by prolonged exposure to hydrocarbons, ethers, etc..

- Division of Research Safety | Illinois

If you have never operated the autoclave you will be using, contact an experienced user in your laboratory for instruction on safe operation. For autoclaves in your building, you may need to contact the facilities manager or department safety contact. For additional assistance; contact the Division of Research Safety at 217-333-2755 or via e-mail.

TOPTION glass reaction vessel, glass reactor, chemical .

Click "+" to select products and contact the supplier Join a shopping cart Hydrothermal synthesis reactor. 25ml ~ 500ml hydrothermal synthesis reactor is stainless steel shell and PTFE liner, temperature is RT-200℃, pressure is 3Mpa, used to break down the refractory material quickly.

Autoclave Standard Operating Procedure

autoclave liquid cycle, however do not submerge the B/ T Sure Indicators in liquid during the autoclave cycle. Simply run the B/T Sure Indicator in the chamber alongside what would be a typical autoclave liquid cycle run (with a normal number of tubes, flasks, etc.) for you or your lab.

Magnetically sealed Glass Reactors up to 6 bar pressure

Glass autoclaves are best option to understand such processes. The glass autoclaves are corrosion resistant and ensure high resistance against various acids, while allowing visual process control and monitoring. Nano-Mag Technologies is a prominent manufacturer and supplier of Glass autoclaves.

Laboratory Autoclaves, Sterilizer Units - Microbiology .

BSL-3 Autoclaves. Our BSL-3 Autoclave is a specially designed double door autoclave for Biosafety Level 3 laboratories. Outfitted with the most advanced features for hazardous sterilization, this pass through autoclave is installed seamlessly for a gas tight fitting between the critical and non-critical side of your laboratory.

FACT SHEET : Using Autoclaves Safely

with your laboratory supervisor, Principal Investigator, or refer to manufacturer's technical services department. Glass: In general, the only glass you should place inside the autoclave is Pyrex or Pyrex type material. Most vendor guides will indicate if a particular brand of glassware may be autoclaved.

"Stirred Autoclave High Pressure Reactor 50ml-250ml"

Removable PTFE / Metal / Glass liners can be offered for autoclaves from 100 ml - 25 ltr. Theseliners can be used for reactions that are corrosive, to prevent the autoclave body from corrosion.PTFE & glass liners can be used upto 200°C & metal upto 500°C. The heat transfer is poor withPTFE & glass liners.

Laboratory glassware, flasks & reactors - Quark Glass

Quark Glass P.O. Box 2396 Vineland, NJ 08362: Toll Free: 1-800-955-0376 Foreign: 856-455-0376 Fax: 856-455-3373 Email: [email protected]@quarkglass.com

Autoclave Safety | Office of Lab Safety | The George .

Autoclaves provide a physical method for disinfection and sterilization. They work with a combination of steam, pressure and time. Autoclaves operate at high temperature and pressure in order to kill microorganisms and spores.PurposeSterilization refers to the complete killing of all living organisms, including spores.

High Pressure/Autoclave Reactor Lab Reactors for sale

100ML Teflon Lined (PTFE) Hydrothermal Synthesis Autoclave Reactor Lab Equipment. 145.00. Free shipping. Make Offer - 100ML Teflon Lined (PTFE) Hydrothermal Synthesis Autoclave Reactor Lab Equipment. High pressure Hydrothermal Autoclave Reactor .

China Hydrothermal Synthesis Reactor Manufacturers and .

300ml Hydrothermal Autoclave With PTFE Liner. 10~2500ml teflon lined hydrothermal synthesis reactor 1.Safe working temperature is 200°C 2.Working pressure ≤3 Mpa (accept SS316 material hydrothermal reactor customization)