Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Buchi® cold-trap condenser, for Rotavapor® evaporators .

Buchi® cold-trap condenser, for Rotavapor® evaporators Inner part, For 210/215; find null-Z319651 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich.

: cold trap

Across International SE05c.110 SolventVap 0.5 gal/2 L Rotary Evaporator with Cold Trap Condenser and Manual Lift, 110V, 1525W, 14 Amp 2,334.75 2,334 . 75 FREE Shipping by Amazon

Mini Rotary Evaporator With Cold Trap For Vacuum .

Mini Rotary Evaporator With Cold Trap For Vacuum Distillation, Find Complete Details about Mini Rotary Evaporator With Cold Trap For Vacuum Distillation,Rotary Evaporator,Rotary Vacuum Evaporator,Mini Rotary Evaporator from Evaporator Supplier or Manufacturer-Shanghai HJLab Instruments Co., Ltd.

Ai SolventVap 2L Rotary Evaporator w/ Cold Trap Condenser .

Standard Glassware Set 0.13 gallon (0.5L), 0.26 gallon (1L) or 0.53 gallon (2 liters) pear shaped evaporating flask, 0.26 gallon (1 liter) round-bottomed receiving flask, and vertical cold trap condenser. Rotary evaporators with vertical condenser are great for distillation of .

Ai T40 Cold Trap for Safe Vacuum Operations | Rotovaps.net

Overview. The Ai 2nd Gen -40°C/F T40 cold traps now all come UL/CSA certified, standard.They have a much smaller footprint, but at the same time, offering you the same cooling power, 1.5X reservoir and 1.6X trap capacity.New upward hose barb ports provide you safer and easier vacuum tubing connection and removal.. In vacuum applications, a cold trap is a device that condenses all vapors .

Ai SolvenVap 5L Rotary Evaporator RotoVap w/ Cold Trap .

Standard Glassware Set includes 1.32 gallon (5 liters) round-bottomed evaporating flask, 0.79 gallon (3 liters) round-bottomed receiving flask, and vertical cold trap condenser. Rotary evaporators .

Antibodies & Protein Biology - Fisher Scientific

Diaphragm pump, cold trap and vacuum gauge (2); Diaphragm pump, cold trap and vacuum gauge, RH40-11 rotor (40 x 1.5-2 mL tube) (1) Diaphragm pump, cold trap and vacuum gauge, RH40-11 rotor (40x1.5-2ml tube) (1) Polypropylene and Stainless Steel spring pressure indicator, Polypropylene flow restrictor and size 16 PVC peristaltic tubing and Nylon fittings (1)

Rotary Evaporator Trap at Thomas Scientific

Two piece cold trap style condenser for use with rotary evaporators. Condenser has a 50mm flange on the side, a 35/20 lower ball joint, a 19/38 stopcock plug .

What is the best method of removing solvents like .

Use acetone and dry ice (solid CO2) in the dewar vessel of the cold trap. This will create a temperature around - 78C, which is sufficient to trap the THF and the chloroform.

CG-1320 - ROTARY EVAPORATOR BUMP TRAPS- Chemglass Life .

Used between the vapor tube and evaporation flask on a rotary evaporator to prevent contents of the flask from being drawn into the condenser in the event of "bumping." Traps have a 24/40 top outer joint and the listed size of lower inner joint. Bump Traps are available Plastic Coated. Contact us .

Rotary Evaporator Instructions | Summit Research

Summit Research Rotary Evaporator Instructions. Please see diagram as this will show you basic link up procedures for the rotary evaporator . We have been educating & training our customers for years on how to properly integrate rotary evaporators with this process.

Rotary Evaporators | Fisher Scientific

Rotary Evaporators; Rotary Evaporators 1 – 30 1132 . Interest Areas. Life Science; Chemicals; Chromatography; Industries; Fisherbrand; Outlet Corner; Events and Exhibitions. The Story of Science World; Activate Science; On-Site Exhibitions; Trade Shows; .

What is the purpose of using the rotary evaporator? - Lab .

After filling the cold traps, you then have to attach a glass bump trap to prevent the solution from entering into the main part of the rotary evaporator. This is made firm by securing it with a Keck clip. After attaching a Keck clip, attach the pump trap and the flask to the adaptor of your rotary evaporator.

How to use a Rotary Evaporator

The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid.

Glass Cold Trap (Dry Ice) Condenser for Ai 2L Rotary .

Ai high quality glass cold trap (dry ice) condenser with lid. No chillers needed, utilizes dry ice for optimal efficiency. Designed and specially made for Ai 2L SolventVap rotary evaporators. Features: - Glass material: high borosilicate glass 3.3 - Vacuum connector: G14 and 3/8" hose barb

Rotary Evaporator Instructions | Summit Research

Summit Research Rotary Evaporator Instructions. Please see diagram as this will show you basic link up procedures for the rotary evaporator . We have been educating & training our customers for years on how to properly integrate rotary evaporators with this process.

Heidolph Instruments : Rotary Evaporators

All Hei-VAP rotary evaporators have a safety heating bath with overheating and dry running protection, ergonomic handles, double wall and an integrated spout . Universal heating bath for all flask sizes up to 5 l (no retooling required). The sturdy metal connection to the device's base allows variable distances for the heating bath up to 200 .

Rotovaps.net | The Largest Selection of Rotary Evaporators!

This bare-bones rotary evaporator is as low-cost as it gets. 2L or 5L models available! based on 6 reviews from 1,158 USD New Rotary Evaporators No sale EcoChyll® X3 Complete Evaporation System. High-efficiency, turnkey evaporation system with 12 L capacity. -40°C condensation with no coolant required. .

Rotary Evaporation to Remove Solvent | Protocol

Rotary evaporation is a technique commonly used in organic chemistry to remove a volatile solvent from a non-volatile compound of interest. Invented by Lyman C. Craig in 1950 the rotary evaporator, or rotovap, gently removes solvents from compounds using heat combined with reduced pressure to evaporate, dry, and purify samples for further downstream use.

Buchi - Fisher Scientific

Buy Buchi products at Fisher Scientific - Buchi are a supplier of laboratory apparatus and instruments for Science, NIR-Spectroscopy.

Buchi Glass Rotary Evaporator Parts - Evaporators | Sigma .

Buchi Glass Rotary Evaporator Parts Assemblies are available in four styles: diagonal, vertical, cold-trap, and cold-trap reflux. They are supplied with either a 24/40 or 29/32 joint on the evaporator flask and a 35/20 ball joint on the receiving flask.

How to hook up cold traps.

Aug 23, 2018 · How To Install Short Path Distillation Apparatus, Connect the Circulating Pump and the vacuum pump - Duration: 14:12. Lanphan Henan 9,671 views

IKA RV 10 Digital Rotary Evaporator With Cold-trap Coated .

Description IKA RV 10 Digital Rotary Evaporator With Cold-trap Coated Glassware, 115 VAC Includes Universal water/oil heating bath, vertical condenser set, 1-L receiving flask with clamp, 1-L evaporator.

: rotary evaporator

Across International SE13c.220 SolventVap 1.3 gal/5 L Rotary Evaporator with Cold Trap Condenser and Motorized Lift, 220V, 2200W, 10 Amp 4,336.16 4,336 . 16 FREE Shipping by Amazon

CG-1320 - ROTARY EVAPORATOR BUMP TRAPS- Chemglass Life .

Used between the vapor tube and evaporation flask on a rotary evaporator to prevent contents of the flask from being drawn into the condenser in the event of "bumping." Traps have a 24/40 top outer joint and the listed size of lower inner joint. Bump Traps are available Plastic Coated. Contact us .

How to select the correct Cold Trap - Labconco

Jun 15, 2015 · How Cold Traps work: In the evaporation process, the Cold Trap is the coldest spot in the evaporation system. Vapors naturally migrate to the coldest spot, where they freeze and are trapped in the condenser. Because of this natural migration of the vapors, Cold Traps can also increase evaporation rates since vapors are collected as a frozen .

Cold Trap|Evaporator related products|Product line-up .

Plenty EYELA product line-up from pre-analysis to production(50 different evaporators).Cold Trap/Product line-up. Rotary evaporator | EYELA as a pioneer of Evaporators

Rotary Evaporators | VWR

Rotary evaporators remove volatile solvents from nonvolatile reaction samples through evaporation. The overall solvent removal rate is increased by reducing the pressure and rotating for even heat application to surface area. This is not only the quickest method, but it eliminates the chance of overheating as the solvent is collected into the .

How to select the correct Cold Trap - Labconco

Jun 15, 2015 · How Cold Traps work: In the evaporation process, the Cold Trap is the coldest spot in the evaporation system. Vapors naturally migrate to the coldest spot, where they freeze and are trapped in the condenser. Because of this natural migration of the vapors, Cold Traps can also increase evaporation rates since vapors are collected as a frozen .

Rotary Evaporator 5L w/ Cold Trap Condenser & Power Lift

The newly re-designed Ai SolventVap 5L (evaporating flask capacity) series rotary evaporators come with all PTFE valves for solvent-resistant operations.